Industry Standards Compliance
Test Results |
|
MANUFACTURER STIPULATES
COMPLIANCE WITH |
STATIC AIR PRESSURE TEST
ASTM E 330; DADE COUNTY BUILDING CODE
COMPLIANCE PROTOCOL PA 202
+76 PSF -76 PSF
3'-0" X 6'-8"
WATER RESISTANCE TEST
ASTM E331; DADE COUNTY BUILDING CODE
COMPLIANCE PROTOCOL PA 202
OUTSWING 8.25 PSF
FORCED ENTRY TEST
ASTM F842; DADE COUNTY BUILDING CODE
COMPLIANCE PROTOCOL PA 202
IMPACT TEST
DADE COUNTY BUILDING CODE
COMPLIANCE PROTOCOL PA 201
CYCLIC WIND LOAD TEST
DADE COUNTY BUILDING CODE
COMPLIANCE PROTOCOL PA 203
+76 PSF -76 PSF
3'-0" X 6'-8"
NATIONAL STANDARDS OF CANADA
CGSB 82.5-M88
DEPARTMENT OF HOUSING AND URBAN DEVELOPMENT
USE OF MATERIALS BULLETIN NO. 89;
AAMA 1702.2
FIRE RESISTANCE TEST
ASTM E152; CSFP 43.7; CAN 4-S104 (ULS S104);
NFFPA 252; UBC 43-2; UL 10(B);
NFPPA 80 90 MINUTE 3'-0" X 6'-8"
AIR INFILTRATION TEST
ANSI/ISDI 101; NFRC 400; ASTM E283
ACOUSTICAL PERFORMANCE TEST
ANSI/ISDI 103; ASTM E90; ASTM E413
STC 26
WATER PENETRATION TEST
ANSI/ISDI 104; ASTM E331
PHYSICAL ENDURANCE TEST
ANSI A151.1; ISDI 105
LEVEL C
THERMAL PERFORMANCE TEST
ANSI/ISDI 107; ASTM C236
NFRC 100
0.18 WITHOUT GLASS
0.25 WITH ½" I.G. QTR LT
0.33 WITH ½" I.G. HALF LT
0.42 WITH ½" I.G. FULL LT
FINISHING INSTRUCTIONS
FOR DOOR TO BE WARRANTED, DOOR MUST BE PAINTED OR
STAINED AND TOP COATED WITHIN 30 DAYS
NOTE: ALL DOORS ARE TO BE ASSEMBLED IN
ACCORDANCE WITH PREM-330
NOTE: ALL DOORS ARE TO BE INSTALLED IN
ACCORDANCE WITH ANSI/ISDI 102.FIRE RATING VOID
IF GLASS LITES ARE INSTALLED |